ERRECI
ERRECI EZCHROM HPLC

ERRECI HPLC SYSTEM - EZCHROM Line

Micro, analytical and semi-preparative liquid chromatography

  • HPLC PUMP FOR GRADIENT UP TO QUATERNARY HIGH OR LOW PRESSURE
  • VARIABLE WAVELENGTH UV-VIS DETECTOR (DUAL WAVELENGTH, SCANNING, OR DAD)
  • REFRACTIVE INDEX DETECTOR
  • FLUORIMETRIC DETECTOR
  • AMPEROMETRIC DETECTOR


Other detectors available upon request

  • COLUMN OVEN (UP TO 6 COLUMNS) COMPLETE WITH VALVE FOR SELECTING THE APPROPRIATE COLUMN BASED ON THE METHOD
  • INLINE DEGASSER UP TO 4 CHANNELS
  • 120-POSITION AUTOSAMPLER (THERMOSTAT AND/OR DERIVATIZATION OPTION)
  • EASY-TO-USE ACQUISITION/MANAGEMENT SOFTWARE
  • TECHNICAL ASSISTANCE (EQUIPMENT) AND APPLICATION MANAGED DIRECTLY BY ERRECI AS THE SOLE INTERLOCUTOR WARRANTY EXTENSION
  • COMPLETE DATA STATION WITH PC AND PRINTER (WINDOWS)
  • PURCHASE, RENTAL OR SERVICE FORMULAS

ERRECI

YI9610 programmable HPLC pump with double reciprocating piston technology

  • ONE PUMP THREE CONFIGURATIONS
  • ISOCRATIC
  • LOW PRESSURE QUATERNARY GRADIENT (LPG)
  • HIGH PRESSURE BINARY GRADIENT
  • MICRO; ANALYTIC; SEMI-PREPARATIVE

Programmable gradient HPLC pump

  • HPLC pump for low pressure quaternary gradient system
  • Double reciprocating piston pumping system with new generation stepper motor;
  • COMPLETE WITH INTERCHANGEABLE PUMPING HEAD
  • Flow: 0.001...10,000 ml/min. (Micro: 0.001-4,000 ml/min) (Semi-Prep 0.1-40,000 ml/min)
  • Flow Reproducibility: Better than 0.1%
  • Maximum Pressure: 400 bar (40 Mpa / 0-6000 psi) (Semi-Prep 20 Mpa @ 20 / 10 Mpa @ 10 ml/min)
  • Flow Accuracy: ≤ 0.05% RSD at 1,000 ml/min
  • Allows Gradients of up to four solvents in low pressure LPG (quaternary)
  • Gradient settable from 0.0 to 100.0% in increments < 0.1%
  • Gradient Accuracy < 0.30%
  • Mixer Volume variable between 10-500 µl

Dual variable wavelength

  • Optical system with holographic grating monochromator
  • Wavelength range 190...900 nm
  • Dual Wavelength readings
  • Acquisition with frequency up to 125 Hz
  • Automatic calibration and self-diagnosis at power-on via Holmium Filter (Internal)
  • Dual source: Deuterium and Quartz Iodine lamp

DAD, DIODE ARRAY DETECTOR

  • Ceramic construction to ensure maximum thermal stability and the best optical performance:
  • Wavelength range 190...950 nm
  • Number of diodes: 1024

Refractive Index Detector

  • Measuring range: 1.00-1.75 RI
  • Analytical flow cell volume 9 µl
  • Analytical flow cell with 45° measuring angle
  • Linearity 0-1000 µRIU

Fluorescence Detector

  • Fully programmable fluorescence detector with double monochromator
  • Measurement range 200-600 nm (optional up to 800 nm)
  • 10 W Xenon flash lamp source with programmable frequency

Autocampionatore per HPLC

  • Easy to use. Intuitive PC interface for simple method and sequence creation.
  • 120-sample tray for 2 ml vials; 192 microplates.
  • Sample thermostating from 4 – 60 °C (Optional).

Column Thermostat Oven

  • Thermostat control from 4°C up to 90°C
  • Temperature accuracy 0.1°C
  • Temperature stability ± 0.03°C
  • Space for the installation of six analytical columns and six pre-columns

Voice connection

ADVANCED POST-COLUMN HPLC APPLICATIONS

POST-COLUMN ION CHROMATOGRAPHY

POST-COLUMN DERIVATIZATION

System Upgrade: Upgrade option with accessories for the post-column derivatization technique used in EPA 326 and DIN EN ISO 11206 methods suitable for the determination of bromates, transition metals, CrVI, amino acids, carbamates, aflatoxins or others.


Available modulesthe

  • Isocratic HPLC pump for derivatization agent management
  • UV/VIS detector for UV applications and post-column derivatization methods
  • LED detector for single applications (CrVI, Bromate, etc.) with post-column derivatization
  • IC Module for transition metals and post-column derivatization methods complete with reaction coil and T-valve

CLARITY

High-resolution chromatographic data acquisition and integration software

  • Complete control of all system elements (management and programming of pumps, detectors, autosamplers, etc.)
  • Simple and attractive graphical interface
  • Compatible with Windows 7 operating systems
  • LIMS (Laboratory Information Management System) support
  • “Multi-tasking” system for data manipulation during acquisition
  • Complete management of the functions of all system components (Flows, Pressures, Wavelength, Gradient, etc.)
  • Programming methods and multi-method sequences
  • Import/Export of data in standard format
  • Simple and complex multilevel calibration curves with linear, quadratic and cubic calculation algorithms
  • Graphical and mathematical reprocessing of data saved on disk
  • Diagnostics of modules inserted into the system
  • - Compliant software CFR 21 Part 11
  • GLP/GMP compliant software with storage of all user operations; Hardware, Software and Method Validation
  • Requires Personal Computer

Contact ERRECI


Contact us to learn how we can support your laboratory.

Contact